HOME UK
MODEL
HMI DISPLAY
SOFTWARE
DOWNLOAD
MANUAL
BROCHURE
POWERSUPPLY
PRICELIST
ORDER
CONTACT
   
Micro ELC6 Serie PLC / CPU*        V5.76
Model Expansion Supply voltage Inputs Outputs High-speed Count PWM HMI RTC Prijs Excl BTW
65-ELC6AC-R No AC 110 ~ 240V 4 digital 2 relays(10A) NO No No Yes Klik
65-ELC6DC-D-R No DC12V - DC24V 4 digital(I1-I4) 2 relays(10A) I7,I8( Max.30k Hz) No No Yes Klik
65-ELC6DC-D-TN No DC12V - DC24V 4 digital(I1-I4) 2 transistors(PNP) I7,I8( Max.30k Hz) No No Yes Klik
*ELC-6 series can not have RS485 unit, actually ELC-6 series can not support expansion feature. However, ELC-6 series CPU can also be connected with third party devices via MODBUS RTU/ASCII, such as HMI
65-RS232   RS232 communication module cable between PC and ELC to program the PLC units 1,8 meter long
Also connection cable between PLC and HMI MD204
Klik
65-RS232-4-5   RS232 communication module cable between PC and ELC to program the PLC units 4,5 meter long
Also connection cable between PLC and HMI MD204
Klik
65-USB   USB communication module cable between PC and ELC to program the PLC units. Windows 98/Vista/Xp. Windows 7 - 32 bits Klik
65-USB146   USB com- module cable to program the PLC units. USB Conv cable+ 65-RS232 Windows 98/Vista/Xp. Windows 7 - 32 bits and 64 bits Klik
 
MODEL
   Standard ELC-12 Series CPU Units       
               
Model Expansion Supply voltage Inputs Outputs High-speed count PWM HMI RTC Price Excl TAX
65-ELC-12AC-R YES AC 110~240V 8 digital 4 relays(10A) NO NO optional yes Klik
65-ELC-12DC-DA-R YES DC12V-DC24V 4 digital/analog(I1-I4) + 4 digital (I5-I8) 4 relays(10A) I7,I8( Max.30k Hz) NO optional yes Klik
65-ELC-12DC-DA-TN YES DC12V-DC24V 4 digital/analog(I1-I4) + 4 digital (I5-I8) 4 transistors(PNP) I7,I8( Max.30k Hz) 2ch(Q3,Q4) optional yes Klik
65-ELC-12DC-DA-TP YES DC12V-DC24V 4 digital/analog(I1-I4) + 4 digital (I5-I8) 4 transistors(NPN) I7,I8( Max.30k Hz) 2ch(Q3,Q4) optional yes Klik











Standard ELC-12 Series Expansion Modules
Model
Supply voltage Inputs Outputs
65-ELC12-E-8AC-R
AC 110~240V 4 Digital 2 Relays(3A,Q1-Q2) +2 Relays(10A,Q3-Q4) Klik
65-ELC12-E-8DC-DA-R
DC12V – DC24V 4 Digital / analog 2 Relays(3A,Q1-Q2) +2 Relays(10A,Q3-Q4) Klik
65-ELC12-E-8DC-DA-TN
DC12V – DC24V 4 Digital / analog 4 Transistors(PNP) Klik
65-ELC12-E-8DC-DA-TP
DC12V – DC24V 4 Digital / analog 4 Transistors(NPN) Klik
65-ELC12-E-PT100
DC12V – DC24V 2 Channels PT100, resolution: 0.1°(12bits), temperature range : -50℃- 200℃
none Klik
65-ELC12-E-AQ-V
DC15V – DC24V None 2 Channels (DC 0…10V), Voltage Signal Klik
65-ELC12-E-AQ-I
DC15V – DC24V None 2 Channels ( 0…20mA) , Current Signal Klik
65-ELC12-E-AI(I)
DC12V – DC24V 4 Channels (0/4…..20 mA), Current Signal none Klik
65-ELC12-E-RS485
DC12V – DC24V isolated 485 converter,used to bring out the terminals of RS485 port built-in ELC-18 series CPU for connection with third party devices. Klik
65-ELC12-ETHERNET-AC
AC 110-240V Ethernet module, Klik
65-ELC12-ETHERNET-DC
DC12V – DC24V Ethernet module Klik



65-ELC12-HMI
Displaying and program-making keypad panel for ELC-12 series CPU , optional, Klik
65-ELC12-COVER-CABLE
Connection cable between ELC-12 CPU and ELC12-HMI-FP (Faceplate) for long-distance application purpose, one and half meters standard length (customizable) Klik
65-ELC12-HMI-FP
Faceplate ( ELC12-HMI’s installation unit), making it possible for ELC12-HMI to be externally installed in the front door of cabinet for easy observation and operation while ELC-12 CPU is required to be installed inside. Klik
65-ELC12-CB-B
connection cable between ELC-12 CPU & Extension module, it can be used to remotely connect ELC-12 CPU to its extension units, 3-meter standard length (customizable) Klik
65-ELC12-COVER
CPU’S cover with 13 LED indicators indicating IO status, if LCD not required, Optional Klik
 
MODEL ELC-xx   DESCRIPTION  
PLC CPU UNITS
  Expansion Supply voltage Inputs Outputs High-Speed Count PWM HMI RTC  PRICE EXCL  
 VAT/BTW 
65-12AC-R without AC 110 - 240V 8 digital 4 relays(10A) NO no no yes Klik
65-12DC-D-R without DC 12 - 24VDC 8 digital 4 relays(10A) 1 Routes(2KHz)* no no yes Klik
65-12DC-D-TN without DC 12 - 24VDC 8 digital 4 transistors(PNP) 1 Routes(2KHz)* 2 ch no yes Klik
65-12DC-D-TP without DC 12 - 24VDC 8 digital 4 transistors(NPN) 1 Routes(2KHz)* 2 ch no yes Klik
65-12DC-DA-R without DC 12 - 24VDC 8 digital/analog 4 relays(10A) 1 Routes(2KHz)* no no yes Klik
65-12DC-DA-TN without DC 12 - 24VDC 8 digital/analog 4 transistors(PNP) 1 Routes(2KHz)* 2 ch no yes Klik
65-12DC-DA-TP without DC 12 - 24VDC 8 digital/analog 4 transistors(NPN) 1 Routes(2KHz) 2 ch no yes Klik
                  Klik
Standard ELC-18 CPU UNITS                         Klik
65-18AC-R available AC 110 - 240V 12 digital 6 relays(10A) None no yes yes Klik
65-18DC-D-R available DC 12 - 24VDC 12 digital 6 relays(10A) 1 Routes(14KHz)* no yes yes Klik
65-18DC-D-TN available DC 12 - 24VDC 12 digital 6 transistors(PNP) 1 Routes(14KHz)* 2 ch yes yes Klik
65-18DC-D-TP available DC 12 - 24VDC 12 digital 6 transistors(NPN) 1 Routes(14KHz)* 2 ch yes yes Klik
65-18DC-DA-R available DC 12 - 24VDC 8 digital/analog+4 digital 6 relays(10A) 1 Routes(14KHz)* no yes yes Klik
65-18DC-DA-RU available DC 12 - 24VDC 8 digital/analog+4 digital 6 relays(10A) 2 Routes(60KHz)* no yes yes Klik
"U" version is a special high- end version with extra functions of:   Manual programming feature via keypad panel, 512 Function blocks, RTC backup time up to 100 hours, Memory write and read block function, 2 - routes high speed counting.
65-18DC-DA-TN available DC 12 - 24VDC 8 digital/analog+4 digital 6 transistor(PNP) 1 Routes(14KHz)* 2 ch yes yes Klik
65-18DC-DA-TP available DC 12 - 24VDC 8 digital/analog+4 digital 6 transistor(NPN) 1 Routes(14KHz)* 2 ch yes yes Klik
                   
EXPANSION MODULES  
   
65-E-16AC-R   AC 110 - 240V 8 digital 4 relays(10A)+4relays(3A)   no Klik
65-ELC-E-AI(I)   DC 12 - 24VDC 4 points current signal input (0/4-20mA) Klik
65-ELC-S-PT100S
           =
(65-ELC-E-PT100)
  DC 12 - 24VDC 3 Channels PT100
-50°c to +200°c    0,1°C
12 bits resolution
Only in combination with analoge PLC
  Klik
65-ELC-E-AQ-V 9 pcs ELC-E-AQ-V can be connected to one standard ELC-18 cpu PLC DC 15 - 24VDC   2 analoge outputs 0 - 10V Signaal Klik
65-E-16DC-D-R   DC 12 - 24VDC 8 digital 4 relays(10A)+4relays(3A)   Klik
65-E-16DC-D-TN   DC 12 - 24VDC 8 digittal 8 transistors(PNP)   Klik
65-E-16DC-D-TP   DC 12 - 24VDC 8 digital 8 transistors(NPN)   Klik
65-E-16DC-DA-R   DC 12 - 24VDC 8 digital/2 analog 4 relays(10A)+4relays(3A)   Klik
65-E-16DC-DA-TN   DC 12 - 24VDC 8 digital/2 analog 8 transistors(PNP)   Klik
65-E-16DC-DA-TP   DC 12 - 24VDC 8 digital/2 analog 8 transistors(NPN)   Klik
ACCESSORIES   DESCRIPTION  
   
65-RS485   RS485 isolated converter Klik
65-RS232   RS232 communication module cable between PC and ELC to program the PLC units 1,8 meter long
Also connection cable between PLC and HMI MD204
Klik
65-RS232-4-5   RS232 communication module cable between PC and ELC to program the PLC units 4.5 meter long
Also connection cable between PLC and HMI MD204
Klik
65-USB   USB communication module cable between PC and ELC to program the PLC units. Windows 98/Vista/Xp. Windows 7 - 32 bits Klik
65-USB146   USB com- module cable to program the PLC units. USB Conv cable+ 65-RS232 Windows 98/Vista/Xp. Windows 7 - 32 bits and 64 bits Klik
65-ELC-BC1   Expansion module, extention ribbon cable 1 meter Klik
65-ELC-BC2   Expansion module, extention ribbon cable 5 meter Klik
65-Ethernet-AC   Ethernet expansion module, 110VAC - 240ACV Klik
65-Ethernet-DC   Ethernet expansion module, 12 - 24DCV  Klik
65-ELC-SMS-D-R   SMS expansion module 24VDC PLC'S I/O status and analogue values etc can be read and sent via SMS Klik
65-SP05AS switching power supply module Dinrail, voltage:5 V, Current: 6A, Gamut voltage: 100-240VAC/140-340VDC Klik
65-SP12AS   switching power supply module Dinrail, voltage:12 V, Current: 3A, Gamut voltage: 100-240VAC/140-340VDC Klik
65-SP24AS   switching power supply module Dinrail, voltage:24 V, Current: 1.5A, Gamut voltage: 100-240VAC/140-340VDC Klik
65-SP05AL   switching power supply module Dinrail, voltage:5 V, Current: 10A, Gamut voltage: 100-240VAC/140-340VDC Klik
65-SP12AL   switching power supply module Dinrail, voltage:12 V, Current: 6A, Gamut voltage: 100-240VAC/140-340VDC Klik
65-SP24AL   switching power supply module Dinrail, voltage:24 V, Current: 3A, Gamut voltage: 100-240VAC/140-340VDC Klik
65-1213114ELC   Switching power supply, Netadapter voltage: 100-240VAC Output 12V 1,2Amp  50/60Hz 2 x Cord end    Klik
80-MS122402   DC Backup Battery Charger, Battery Guard and Batterij UPS, For 12V and 24V lead / Lood Accu / Battery    Klik
65-ALE1202   30Watt Switching power supply, 220 - 240VAC Output 10V ~ 15VDC Adj. 2Amp.  Protect against short-circuits by circuit breaker with auotmatich reset. Protect against transients on the primary circuit by fuse. Portect against overcurrent on primary circuit by fuse.     Klik
65-ALE2401   30Watt Switching power supply, 220 - 240VAC Output 20V ~ 30VDC Adj. 1Amp.  Protect against short-circuits by circuit breaker with auotmatich reset. Protect against transients on the primary circuit by fuse. Portect against overcurrent on primary circuit by fuse.     Klik
       
65-ELC-COPIER   Easy xLogic ELC-COPIER: Program the PLC Software in your office, upload it to the ELC-COPIER , and take this copier unit with you to the customer, then download the programming for the customer in the PLC. ELC-COPIER which can be used to save/take off user program from PC, and further copy it to xLogic CPU units without need for PC on site.  Klik
65-MD204LV4 = AR3057SL HMI 4,2" Programmable Display 12 - 24VDC Klik
65-MD306L   HMI 4,2" Programmable Display, met Real Time Clock 12 - 24VDC Klik
65-UT-AA5-7   UT-AA 5.7" Color HMI Touch Screen. Touch Screen include RS485 + Ethernet LAN + 2 x USB port + 2 x RS232 Comport Klik
65-UT-AA80   UT-AA 8" Color HMI Touch Screen. Touch Screen include RS485 + Ethernet LAN + 2 x USB port + 2 x RS232 Comport Klik
65-xLogicV2-0   Programming software on cdrom ( download on internet is free of charge) go to this webpage of xLogicsoft Klik
€ NA,00 = is not available on this moment

* Route means channel. Only the "Threshold trigger" function block can receive the high speed (frequency) input. And on the xLogic SuperRelay ,not all the inputs can been used as "high speed input"

© Copyright 2011 PLCshop xLogic SuperRelay European Sales   |    Contact Us